9.LASER SOFTWARE FUNCTION B-70315EN/02
- 258-
9.1 MAINTENANCE SCREEN
9.1.1 Overview
The maintenance screen displays maintenance information for
preventive maintenance and troubleshooting of the laser oscillator.
(1) Compensation coefficient history display
The compensation coefficient for power compensation and the
discharge voltage RFV1 for No. 1 power supply are preserved
and can be referenced at a later time.
(2) Run time display of each part
The cumulative run time of each part that requires periodic
maintenance is displayed.
(3) Discharge-related alarm history display
Preserved discharge-related alarm data can be referenced at a
later time.
9.1.2 Method of Operation
(1) Set bit 0 (MNT) of parameter No. 15160 to 1 to enable
maintenance screen display.
#7 #6 #5 #4 #3 #2 #1 #0
15160 MDS MNT
MNT
0 : Does not display the laser maintenance screen.
1 : Displays the laser maintenance screen.
MDS
0 : Disables data input on the laser maintenance screen.
1 : Enables data input on the laser maintenance screen.
(2) Press the "Setting" operation key on the CNC.
Then, press the soft keys at the bottom of the CNC screen as
follows:
POWER SET DATA
STATUS MAINT.
PW.OFS ACT.TM ALARM
Operation time display Run time display
Discharge-related
alarm display