B-70315EN/02 9.LASER SOFTWARE FUNCTION
- 259 -
9.1.3 Display Information
9.1.3.1 Compensation coefficient history display
When the power compensation coefficient setting function is operated,
a power compensation coefficient and the current RFV1 value and
date/time are preserved. Up to 30 items of data can be recorded. If this
limit is exceeded, the oldest data is deleted to record new data.
Pressing the [PW.OFS] soft key displays the power compensation
coefficient history screen.
This screen consists of three pages. One page displays ten
compensation coefficients. Data with younger dates is displayed in
upper fields on the screen. When a new compensation coefficient is
registered, it is displayed on the top line of the first page.
To switch pages, use the "PAGE ↑" and PAGE ↓" keys on the MDI
panel. The preserved compensation coefficient data cannot be edited.
9.1.3.2 Parts run time display
Pressing the [ACT.TM] soft key causes the operation time display
screen to be displayed. If you enter a limit time in a set time field in
advance, the operation time display will turn red when the operation
time exceeds 90% of the set time. If it exceeds the set time, the
operation time display in red reverse video.
The set time and the operation time are in 0.1-hour units.
To switch pages, use the "PAGE ↑" and PAGE ↓" keys on the MDI
panel.