B-70315EN/02 APPENDIX E.PARAMETER LIST
- 311 -
E.7 PARAMETERS FOR POWER CONTROL
#7 #6 #5 #4 #3 #2 #1 #0
15088 IPC
[Data type] Bit (Power-off)
IPC The power control mode is:
0: Specified by using the format where S and F are specified in the
same block.
1: Specified with G63 or by using the format where the external
signal (G224#1) is input.
#7 #6 #5 #4 #3 #2 #1 #0
15089 LP8 LP7 LP6 LP5 LP4 LPZ LPY LPX
[Data type] Bit
LP*
0: Does not use the *-axis for speed calculation for the power
control function.
1: Uses the *-axis for speed calculation for the power control
function.
If no bit is specified, the power control function operates, assuming
the first axis (LPX) and second axis (LPY) to be specified.
Ordinarily, specify each axis to be used for interpolation. Do not
specify a synchronously controlled axis for simple synchronous
control or PMC axis.
15090 Minimum output power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
15091 Minimum pulse frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
15092 Minimum pulse duty ratio
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
Set the minimum pulse duty ratio.