E.PARAMETER LIST APPENDIX B-70315EN/02
- 314 -
E.8 PARAMETERS FOR ASSIST GAS PRESSURE AND TIME
SETTING
15100 Selection of assist gas
[Data type] Word
[Unit of data]
[Valid data range] 0 to 7
Select a type of assist gas.
15101 Selection of flow pattern
[Data type] Word
[Unit of data]
[Valid data range] 1 to 3
Select a assist gas flow pattern.
15102 Pre-flow time 1
15103 Pre-flow time 2
15104 Pre-flow time 3
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set the assist gas pre-flow time.
15108 After-flow time 1
15109 After-flow time 2
15110 After-flow time 3
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set the assist gas after-flow time.
15114 Pre-flow pressure 1
15115 Pre-flow pressure 2
15116 Pre-flow pressure 3
[Data type] Word
[Unit of data] 0.01MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Set the assist gas pre-flow pressure.