E.10 PARAMETERS FOR THE OSCILLATOR
15200
Power used for power compensation factor determination when half of the
discharge tubes are used
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
Set a power to find the power compensation factor when half of the
discharge tubes are used.
15201
Power used for power compensation factor determination when all
discharge tubes are used
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
Set a power to find the power compensation factor when all discharge
tubes are used.
15203 Power calibration limit
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
If the power compensation factor exceeds this value, the low output
alarm signal (F220#6 MWRN) is output to notify the user of the time
to clean or replace the mirror.
15204 Power calibration coefficient
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
This is to calibrate command power for real power. This parameter is
automatically set at power compensation after the oscillator start
signal (G222#6 RUN) is turned on.
15205 Power compensation time
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
Set a power compensation time.