E.PARAMETER LIST APPENDIX B-70315EN/02
- 340 -
29003 Peak power in power sensor time constant measurement
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
[Standard setting value]
Set a peak power in measurement of the time constant of the power
sensor.
Usually, set the rated output of the oscillator.
29004 Beam output time in power sensor time constant measurement
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
[Standard setting value]
Set a period of time for which a beam is output to measure the time
constant of the power sensor.
29005 Power sensor time constant
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
[Standard setting value]
Set a time constant for the power sensor.
Usually, the power sensor time constant measurement screen is used
to set this parameter.