B-70315EN/02 3.INSTALLATION
- 49 -
3.1 INSTALLATION PROCEDURE
Use the following procedure to make adjustments and checks during
installation.
As soon as the oscillator is delivered, loosen the clamps of the
resonator described in (2) below.
CAUTION
If the clamps of the resonator are left fastened for a
long time, the resonator can deform. As a result, a
problem such as a failure in beam mode
adjustment or insufficient laser output can arise.
(1) Check the environment at the installation location.
[Environmental conditions]
1 Ambient temperature +5 to 30°C
2 Temperature variation 1.1°C /minute maximum
3 Humidity 75% or below (relative humidity)
4 Vibration
Acceleration not to exceed 0.05G.
Vibration amplitude not to exceed 5µm.
5 Atmosphere
Dust must be minimized.
There must be no organic volatile
components. There must be no
flammable gas or dangerous gas such
as oxygen.
(2) Remove resonator and shutter clamps.
The clamp locations are shown in Figs.3.1(a) to (e).
Fig.3.1(a) Clamp locations (C1000-E)