A-79595E
Title
Draw
No.
Ed. Date Design Description
Date May.24.’04 esig. Apprv.
10/33
Sheet
FANUC Series 30i-MODEL A
Live Tool Control With Servo Motor
(2) Servo parameter setting
Set the servo parameters as listed below:
CMR=1, DMR=36/100
(With the above setting, the reference counter capacity is 360000.)
No. 1820 (C)=2 (CMR)
No. 1821 (C)=360000 (reference counter capacity)
No. 2084 (C)=36 (DMR numerator)
No. 2085 (C)=100 (DMR denominator)
If the tool axis and motor gear ratio is 1:1
No. 11015 (C) = 5000 (Maximum motor speed)
No. 3741 (S2) = 5000 (Maximum spindle speed for gear 1)
For the other servo parameters, specify typical values.
Signal
SV speed control mode signals SRVON1 to SRVON8<Gn521>
[Classification] Input signal
[Function] These signals switch the corresponding axes to SV speed control mode.
[Operation] Setting these signals to 1 causes the corresponding axes to enter SV speed
control mode.
Setting these signals to 0 causes the corresponding axes to exit from SV
speed control mode.
NOTE
Even if these signals are 1, if SV speed control mode is
turned OFF (SV speed control mode in-progress signal
Fn521 becomes 0), the spindle control function is not
enabled. To enable it, set these signals again.
SV speed control mode in-progress signals SVREV1 to SVREV8<Fn521>
[Classification] Output signal
[Function] These signals report that the corresponding axes are in SV speed control
mode.
[Output condition] They become "1" if:
・The corresponding axes are in SV speed control mode.
They become "0" if:
・The corresponding axes are not in SV speed control mode.
・The corresponding axes are in position control mode.