FANUC Series 16i/18i/21i-MB/TB,18i-MB5
Diagnosis screen for Dual Check Safety
Function Specifications
2002.11.19 T.Inagaki E.Genma
4/
14
A-78974E
02 030714 T.Inagaki (2) is altered
02 030714 T.Inagaki (2) is altered 02 030714 T.Inagaki (2) is altered
02 030714 T.Inagaki (2) is altered
1.2
Screen display
The present machine condition
(1) General
[ 1 page ]
• Safe signal mode (SAFE MODE) is displayed.
The kind and priority of the safe signal mode are as follows.
Priority Kind
EMERGENCY STOP
MCC off TEST
A) NORMAL MODE
B) GUARD opening REQ
C) GUARD opening
High .
Low .
D) ILLEGAL MODE
The priority of A) - D) are same.
• The last MCC OFF test execution time (LAST MCC off TEST) is
displayed.
In case that no execution of MCC off test, “NO TEST” is displayed.
• The reason of LGD=0 is displayed. The display items are as
follows.
Display item
ORQ=0 (NO opening REQUEST)
RQT=1 (MCC off TEST REQUEST)
ILLEGAL MACHINE POSITION
ILLEGAL SPEED
ILLEGAL SPINDLE SPEED
ALARM STATES
In case of LCG=1, “0” is displayed for all items.
Screen layout