This signal set to 0 when any of the following conditions is satisfied.
The two spindles have not reached the speed corresponding to a specified
spindle synchronous speed on spindle synchronization mode.
The speed difference between the two spindles is greater than the value set
in parameter No.4033 on spindle synchronization mode.
Spindle synchronization mode is not set.
Note
Even if this signal set to 1 once, this signal set to 0 when the speed difference
becomes equal to or greater than the value set in parameter No.4033 for
a cause such as cutting load variation.
Spindle phase synchronous control completion signal FSPPH
[Classification] Output signal
[Function] Posts that spindle phase synchronous control (phase matching) is completed.
[Output condition] This signal is set to 1 when the following condition is satisfied.
This signal is output when phase matching is completed with the spindle
phase synchronous control signal (the error pulse difference between the
two spindles is equal to or less than the value set in parameter No.4810)
after the two spindles have reached the speed corresponding to a specified
spindle synchronous speed on spindle synchronization mode.
This signal is set to 0 when any of the following conditions is satisfied.
Phase matching between the two spindles is not completed on spindle
synchronization mode.
The error pulse difference between the two spindles is greater than the
value set in parameter No.4810 on spindle synchronization mode.
Spindle phase synchronous control mode is not set.
Edit
12
17
A-78807E
Drawing No.
Page
Date
Design
Descri
tion
Date
2004/07/02
Design
K.Yamamuro
Approv.
FANUC Series 16i/18i/21i-TB
Spindle synchronous control
Title