4. Signal
Spindle synchronous control signal SPSYC
[Classification] Input signal
[Function] Specifies switching to spindle synchronization mode
[Operation] When this signal set to 1, spindle synchronization mode is set.
When this signal set to 0, spindle synchronization mode is cancelled.
Note
This signal is effective only for spindle synchronous control by PMC DI signal
Spindle phase synchronous control signal SPPHS
[Classification] Input signal
[Function] Specifies spindle phase synchronous control mode (phase matching).
1. This function is valid when the spindle synchronous control signal SPSYC
is 1.
2. After the spindle synchronous speed control completion signal FSPSY is set
to 1m specify this signal.
3. A spindle phase synchronous control operation is performed on the rising
edge of this signal. So, the phase once matched is not shifted by setting this
signal to 0.
However, a phase matching operation is performed when this signal is changed from 0 to 1
again.
[Operation] When this signal make a transition from 0 to 1, spindle phase
synchronous control is exercised.
Note
This signal is effective only for spindle synchronous control by PMC DI signal
Velocity integral control signal INTGA,INTGB,INTGC,INTGD
[Classification] Input signal
[Function] Enables or disables velocity integral control.
[Operation] When this signal set to 1
The velocity loop integral function is disables. This has a same effect as the
setting of a velocity loop integral gain of 0.
When this signal set to 0.
The velocity loop integral function is enabled.