FANUC Series 16i/18i –TB
A
bout the cancellation of the superimpose control
Aug.13.2002
2/2
Sheet
1. OutLine
The P/S000 alarm is generated when the superimpose control is interrupted by reset and the alarm, etc. while the
axis is moving by superimpose control. The generation of this alarm can be selected by the parameter setting.
2. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
8165 NA0
[
[[
[Data type
Data typeData type
Data type]
]]
]Bit
NA0
NA0NA0
NA0 When the superimpose control is canceled while the axis is moving,
0: P/S000 alarm is generated.
1: P/S000 alarm is not generated.
When the superimpose control is canceled while the axis moving, alarm of
P/S225 is generated.
3. Note
l When parameter 8165#3(NA0) is ‘1’, parameter 1300#7(BFA) becomes invalid in superimpose control mode.
When parameter 8165#3(NA0) is ‘0’, parameter 1300#7(BFA) becomes effective while superimpose control mode.

Contents Summary of FS 16i/18i-TB, About the Cancellation of the Superimpose Control Supplement to Manual

  • Page 1FANUC Series 16i /18i –TB About the cancellation of the superimpose control FANUC Series 16i/18i –TB Title About the cancellation of the superimpose control Draw No. A-78914E Edit Date Design Description Sheet 1/2 Date Aug.13.2002 Desig. Apprv.
  • Page 21. OutLine The P/S000 alarm is generated when the superimpose control is interrupted by reset and the alarm, etc. while the axis is moving by superimpose control. The generation of this alarm can be selected by the parameter setting. 2. Parameter #7 #6 #5 #4 #3 #2 #1 #0 8165 NA0 [Data type] type] Bi