1. General
By this function, the manual handle feed magnification m, n can be set for each axis
individually with setting the parameter No.12350 and No.12351.
When the parameter No.12350 is set to “0”, the parameter No.7113 is used for the
magnification m and when the parameter No.12351 is set to “0”, the parameter No.7114 is
used for the magnification n.
As for the manual handle interruption, the parameter No.12350 and No.12351 are effective
for the magnification.
2
4
Edit
Apprv. Desig.
Sheet
Title
Draw
No.
Date
Design
Descri
tion
Date
May.17.2004
Sheet
FS16i/18i/21i - B, 18i - MB5, 0i - B
Manual handle feed magnification for each axis
Specifications
A-78860E