16i/18i/21i analog servo interface
unit connection material
A-77372EN
1.10 Parameter setting
1) In emergency stop condition, turn on the 16i/18i/21i.
2) Follow the procedure below to set parameters concerned with FSSB.
In the case of using an analog servo interface unit, the FSSB automatic setting function
is not available. It is necessary to set the value of No.1023, No.1905, No.1910-1919, No.1936,
No.1937 in the manual setting No.2 mode. Refer to “FSSB setting” of the connection
manual (function edition) about the detail of the setting.
When this parameter is set, the analog servo interface unit is basically treated in the
similar way to the separate type detector interface unit. (After this, the analog servo
interface unit and the separate type detector interface unit are called “an interface unit”.)
Follow the explanation below and the parameter manual of 16i/18i/21i and set the
appropriate value.
{The parameter to be set}
Data No. Setting value Description
No.1023 referred in “1” Servo axis number of each axis
No.1815 referred in 2 Separate type pulse coder setting
No.1902, B0 referred in “3” Validity of FSSB manual setting function
No.1905 referred in “4” (Bit type parameter)
No.1910-1919 referred in “5” The value of Address Conversion Table
No.1936 Connector number of the first interface unit
No.1937
referred in “6”
Connector number of the second interface unit
“1”Setting of servo axis number
Number of the servo axis for each axis
Data type: Byte
Valid data range: 1,2,3,…controllable axis number
Set the servo axis number for each axis.
Refer to the “FSSB setting” of connecting manual (function edition).
2. Separate type pulse coder setting
No. 7 6 5 4 3 2 1 0
1815 APC APZ OPT