Basic SPINDLE Tuning using SERVO GUIDE
4. Tuning of Rigid tapping
4.1. Tuning time constant.
It is necessary to determine maximum spindle speed and to tune time constant properly at first.
(1) Parameters
Following parameters corresponding to gear signals (GR1, GR2 / GR1O, GR2O, GR3O) are prepared
to determine the time constant on rigid tapping.
Parameter No
16i/18i/21i, 0i
Gear signals
T series M series
Standard
setting
Description
T series
GR1, GR2
M series
GR1O, 2O, 3O
5241 5241 0 Maximum spindle speed on rigid tapping (min
-1
) 0, 0 1, 0, 0
5242 5242 0 Maximum spindle speed on rigid tapping (min
-1
) 1, 0 0, 1, 0
5243 5243 0 Maximum spindle speed on rigid tapping (min
-1
) 0, 1 0, 0, 1
5244 - 0 Maximum spindle speed on rigid tapping (min
-1
) 1, 1 -
5261 5261 0 Time constant on rigid tapping (ms) 0, 0 1, 0, 0
5262 5262 0 Time constant on rigid tapping (ms) 1, 0 0, 1, 0
5263 5263 0 Time constant on rigid tapping (ms) 0, 1 0, 0, 1
5264 - 0 Time constant on rigid tapping (ms) 1, 1 -
(2) Tuning procedure
Determine the time constant according to following steps
<1> Determine
maximum spindle speed on rigid tapping for each gear.
<2> Accelerate spindle from stop state (0 min
-1
) to determined maximum spindle speed on rigid
tapping at velocity control mode.
<3> Observe motor speed (SPEED) waveform at acceleration by SERVO GUIDE.
<4> Determine minimum time constant “T
min
” from waveform at acceleration according to following
example.
<5> Set 1.5 times longer value of “T
min
” as time constant for rigid tapping.
[Example of determining time constant]
Tangent to SPEED waveform near
the maximum speed.
T
min
=200 ms
SPEED
Time constant:
= T
min
*1.5 = 300 ms
A-53866E-456/05 (23/34)