Change of Design on the 15.0 Additional Manual Page 2

Additional Manual
Edit. DATE Design
Description
DRAW. NO.
A-85120E
CUST.
TITLE
Change of design on the 15.0 LCD
units
SHEET
1 / 2
Change of design on the 15.0 LCD units
Abstract
In 15.0 LCD units for PANEL i , FS30i/300is series, FANUC will apply the new 15.0 LCD units
to systems provided from December 2004. It is caused the production stoppage by LCD
manufacturer.
The new 15.0 LCD units have fully compatibility with current display units.
The color tone changes though it is just a little.
There is no need to change the order number of these systems in regard to this change.
The LCD module used in the new 15.0 LCD units has compatibility with current LCD module about
the dimension. But the cable to connect PCB and the LCD module is different. So, the new
maintenance units that contained a new LCD module and a new cable for the maintenance exchange
were developed. For maintenance use, you must order the new 15.0 maintenance unit instead
of a single LCD module.
1. Applied system
Change is applied to 15.0 LCD units of the systems below.
1) PANEL i
2) FS30i/300is series
2. Applied period
In December, 2004, from the shipping unit
3. List of 15.0 LCD units
1) PANEL i
Order numbers
Current 15.0 LCD unit
for maintenance
New 15.0 LCD unit
for maintenance
A08B-0084-B021
A13B-0196-B021
A08B-0084-D021 A08B-0084-D025
A08B-0084-B023
A13B-0196-B023
A08B-0084-D023 A08B-0084-D027
A07B-0045-H221
A07B-0045-H222
A08B-0084-D053 A08B-0084-D057
A08B-0084-B400
A13B-0196-B400
A08B-0084-D400 A08B-0084-D420
A08B-0084-B401
A13B-0196-B401
A08B-0084-D401 A08B-0084-D421
A08B-0084-B402
A13B-0196-B402
A08B-0084-B422
A13B-0196-B422
A08B-0084-D402 A08B-0084-D422
01 04.11.19 Nogami New issue.

Contents Summary of Change of Design on the 15.0 Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) NO.TMN 04/ 115E Date Nov. 19, 2004 General Manager of CNC Laboratory PANEL i , FS30i/300is series Change of design on 15.0” LCD units 1.Communicate this report to: ○ Your information only ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON ○ Machine tool builder Sal
  • Page 2Change of design on the 15.0” LCD units Abstract In 15.0” LCD units for PANEL i , FS30i/300is series, FANUC will apply the new 15.0” LCD units to systems provided from December 2004. It is caused the production stoppage by LCD manufacturer. The new 15.0” LCD units have fully compatibility with curre
  • Page 3A08B-0084-B403 A08B-0084-D403 A08B-0084-D423 A13B-0196-B403 A08B-0084-B423 A13B-0196-B423 A08B-0084-B410 A08B-0084-D410 A08B-0084-D430 A13B-0196-B410 A08B-0084-B411 A08B-0084-D411 A08B-0084-D431 A13B-0196-B411 A08B-0084-B412 A08B-0084-D412 A08B-0084-D432 A13B-0196-B412 A08B-0084-B432 A13B-0196-B432