Title 90A3 / 90A7 / 90B3 / 90B7
Learning Control Operator’s Manual
03 ’05.01.13 K.Maeda 3
rd
. updated. Draw No.
02 '03.01.06 K.Maeda 2
nd
. updated
A - 63639E - 070
01 ’00.09.20 K.Maeda Newly designed Sheet 065
Edit Date Design Description / 081
(Note 1) You need to set the Learning parameter value because of not auto-Loading.
In case of adding “( )” at Motor ID, you need to set value to No.2228 and below with coloring frame
after auto-Loading.
(Note 2) Regarding High-gain parameter setting for the other motor, refer to 5.2 Setting High-gain
parameters.
Standard Parameters for Learning Contorl (Linear moto 2 / 5
Motor type 6000B 600D/4 900D/4
Motor spec. 0412 422 423
Motor ID (92) (125) (126)
Velocity 0.5ms 0.5ms 0.5ms
Remarks Piston Ring
Amplifiler 80Ap 40Ap 40Ap
Pg No.1825 5000 5000 5000
PI No.2003
00001000 00001000 00001000
Interrupt No.2004
00100001 00100001 00100001
High speed No.2005
00000010 00000010 00000010
HS Veloc. No.2007
00000000 00000000 00000000
Learning No.2008
00111000 00110000 00110000
Linear No.2010
00000100 00000100 00000100
HRV3 No.2013
xxxxxxx0 xxxxxxx0 xxxxxxx0
PK1 No.2040 6833 720 480
PK2 No.2041 -12667 -5537 -3691
PK3 No.2042 -1603 -763 -763
PK1V No.2043 23 11 16
PK2V No.2044 -623 -731 -1073
PK4V No.2046 -14412 -24708 -24708
PPMAX No.2053 21 21 21
PDDP No.2054 1894 1894 1894
PHYST No.2055 319 319 319
TRQLIM No.2060 7282 6554 7282
POVC1 No.2062 32670 32731 32685
POVC2 No.2063 1222 463 1041
POVCLM No.2065 3626 1373 3089
RTCURR No.2086 1402 862 1293
MGSTCM No.2110 0 0 0
FBND No.2244 200 150 150
GODMX No.2246 5 15 15
GODMN No.2247 0 0 0
GCOEF No.2248 384 64 64
EXGX K2 No.2249 -51 -32 -32
EXGX K3 No.2250 -223 0 0
EXGX K4 No.2251 -214 0 0
EXGX K5 No.2252 -1 0 0
EXGX K6 No.2253 137 0 0