Title 9083 / 9087 / 90A3 / 90A7
Learning Control Operator’s Manual
03 '00.06.07 N.Sonoda Qualified 2'nd issue Draw No.
02 ’99.01.14 K.Maeda Qualified 1’st issue
A - 63639E - 034
01 ’97.12.08 K.Maeda Newly designed Sheet 059
Edit Date Design Description / 070
(Note 1) You need to set the Learning parameter value because of not auto-Loading.
(Coloring frame)
(Note 2) The “xxxx” or blank frames show standard setting.
(Note 3) Regarding High-gain parameter setting for the other motor, refer to 5.2 Setting High-gain
parameters.
Standard parameter setting for Learning control
4/4
Motor Model
IP-control PI-control High gain
Motor Spec.
Motor ID.
Velocity 1ms 1ms 0.5ms
Remark C-axis C-axis
Amp.
Pg No.1825 3000 3000 6000
PI No.2003
xxxx0xxx xxxx1xxx xxxx1xxx
INT. etc No.2004
xx0x0110 xx0x0110 xx1x0001
High speed
No.2005
00000000 00000000 00000000
HS veloc. No.2007
00000000 00000000
00010000
Learning No.2008
00110000 00110000 00110000
PK1 No.2040 standard x2
PK2 No.2041 standard x2
PK3 No.2042
PK1V No.2043
PK2V No.2044 standard x2
PK4V No.2046
PPMAX No.2053
PDDP No.2054
PHYST No.2055
TRQLIM No.2060
POVC1 No.2062
POVC2 No.2063
POVCLM No.2065
RTCURR No.2086
PIIPL No.2230
FBND No.2244 100 100 200
GODMX No.2246 15 13 10
GODMN No.2247 0 0 0
GCOEF No.2248 64 64 64
EXGX K2 No.2249 -32 -32 -32
EXGX K3 No.2250 0 0 0
EXGX K4 No.2251 0 0 0
EXGX K5 No.2252 0 0 0
EXGX K6 No.2253 0 0 0