Edit Date Design Contents
Title
of
Drawin
Drawing
No.
FANUC Series 16/160i-LA/LB
Automatic aging function setting screen
Specification
A-79279E
Page
6 / 7
Recog
nition
Newly designed
Suzuki
Tokito
04.01.05 01
Item #1 corrected.
Suzuki
Tokito
04.09.29 03
ll revised.
Suzuki
Tokito
05.03.25 04
Name POWER(HALF)
Meaning Laser power command for power calibration in case of using half of discharge
tubes.
Parameter
No.15200
Setting range
0~9999
Name POWER(ALL)
Meaning Laser power command for power calibration in case of using all of discharge
tubes.
Parameter
No.15201
Setting range
0~9999
Name FREQUENCY
Meaning Laser output frequency for power calibration.
Parameter
No.15321
Setting range
0~2000
Name DUTY
Meaning Laser output duty for power calibration.
Parameter
No.15322
Setting range
0~100
Name CAL. TIME
Meaning Execution time of power calibration.
Parameter
No.15205
Setting range
0~32767
Name GAS PRESS.(50HZ)
Meaning Laser gas pressure during oscillation. (50Hz)
Parameter
No.15242
Setting range
0~32767
Name GAS PRESS.(60HZ)
Meaning Laser gas pressure during oscillation. (60Hz)
Parameter
No.15243
Setting range
0~32767
2.3. Manual start up for aging function
If you want to start the aging function by manual operation when you maintain the oscillator, you
can set the aging function to start by aging setting screen. The item “”MANUAL MODE” on the page
1 is “0” when CNC is turned on. By RUN-ON after setting the item "MANUAL MODE" to “1” on the
page 1 of aging setting screen, aging function starts according to the item "SET MANUAL TIMES"
irrespective of setting value of parameter No.15008#6 or oscillator stop time. The item “MANUAL
MODE” becomes “0” automatically when laser oscillator becomes LSTR status after aging function
is completed. If this item is set after RUN-ON, this setting is not available and manual aging
function set by this item does not work. This setting is determined by timing of RUN-ON. Thus the
action of aging function does not change if this setting is changed when aging function is executed.