A-79118E
Edit
Apprv. Desig.
Sheet
Title
Draw
No.
Date
Design
Descri
tion
Date
FANUC Series 16i/18i/21i –TB/MB
Spindle speed override for each spindle
(Improvement of multi-spindle)
Sheet
3
5
3.Signals
Spindle speed override signal of each spindle
1st spindle speed override signal [Classification] Input signal
SOV0~SOV7<G030> [Function] In the case of parameter EOV (No.3713#4)=1, the spindle speed
2nd spindle speed override signal commanded from CNC can be overridden for each spindle to 0%~254%.
SOV20~SOV27<G376> [Operation] An override value in binary must be set in 8 bits.
3rd spindle speed override signal But, in the case that all bits are “1”, override value is regarded as 0%.
SOV30~SOV37<G377>
4th spindle speed override signal
SOV40~SOV47<G378>
NOTE) In the case of parameter EOV (No.3713#4)=0, SOV0~SOV7 become override
signals for all spindles commanded the spindle speed from CNC. And, SOV20~27,
SOV30~37, SOV40~47 are disabled.
path 2
override
override
override override
override
override 1st spindle
#2
3rd spindle
#1
2nd spindle
#1
1st spindle
#1
2nd spindle
#2
3rd spindle
#2
S command
path 1
Fig.4 Parameter EOV(No.3713#4)=1 (two-path)
SOV0
#2
~7
#2
SOV20
#2
~27
#2
SOV30
#2
~37
#2
SOV0
#1
~7
#1
SOV20
#1
~27
#1
SOV30
#1
~37
#1