Contents Summary of 16i/18i-MA/TA Spindle Synchronous Control with any spindle Additional Manual
Page 1PUN-F01/004 SPEC01/009 FANUC Series 16i/18i-MA/TA Spindle Synchronous Control with any spindle Specifications 1. General ................................................................................ 2 2. Specification......................................................................... 2 3. S
Page 21. General This enhancement enables you to select any pair for Spindle Synchronous Control out of 1st to 4th spindles(1st to 3rd spindles in case of 18i). It is available only for serial spindles. 2. Specification Spindle Synchronous Control realizes spindle synchronization between one master spindl
Page 33. Signals Spindle synchronization signals SPSYC1 to SPSYC4 [Classification] Input signal [Function] Enable Spindle Synchronous Control. [Operation] When SPSYC1 is 1, 1st spindle will be synchronized as slave. When SPSYC2 is 1, 2nd spindle will be synchronized as slave. When SPSYC3
Page 4Spindle speed synchronization completion signals FSPSY1 to FSPSY4 [Classification] Output signal [Function] Indicate spindle speed synchronization is completed. [Operation] These signals will turn “1” when both master and slave spindles reach commanded speed(rotation number) and th
Page 5Synchronous error monitoring signals SYCAL1 to SYCAL4 [Classification] Output signal [Function] Monitor synchronous errors between master and slave spindles. [Operation] These signals will turn “1” when the synchronous errors(absolute value) between master and slave spindles exceed
Page 64. Parameters #7 #6 #5 #4 #3 #2 #1 #0 3704 SSS Data type : Bit SSS Enhanced Spindle Synchronous Control is: 0: disabled 1: enabled You can select any pair for Spindle Synchronous Control out of 1st to 4th spindles. Master for each slave is specified in the parameters No.4831 to 4834. NOTE1) It is av
Page 7#7 #6 #5 #4 #3 #2 #1 #0 4800 ND4 ND3 ND2 ND1 Data type : Bit ND1 1st spindle in spindle synchronous control mode rotates: 0: in the same direction as commanded sign 1: in the opposite direction as commanded sign ND2 2nd spindle in spindle synchronous control mode rotates: 0: in the same direction as
Page 84034 Shift amount in spindle phase synchronization Data type : Word axis Data unit : 1pulse(360deg./4096) Data range : 0 to 4095 Specify shift amount from reference point(1 rotation signal) in spindle phase synchronization. 4810 Permissible error pulses in spindle phase synchronization Data type : B
Page 95. Diagnostic Screen 425 Position errors of 1st spindle 426 Position errors of 2nd spindle 427 Position errors of 3rd spindle 428 Position errors of 4th spindle When spindles are position-loop controlled, position errors for each spindle are displayed by the unit of used detector in each mode. 429 S
Page 106. Spindle Tuning Screen In spindle synchronous control mode, the following information is displayed on spindle tuning screen. MOTOR SPINDLE POS ERR S SYN.ERROR The screen can be switched for each spindle by pressing PAGE key. “MOTOR” shows motor speed. “SPINDLE” shows spindle speed. “POS ERR S” sho
Page 119. References FANUC Series 16i/18i/21i/160i/180i/210i CONNECTION MANUAL(FUNCTION) B-63003EN 9.12 SPINDLE SYNCHRONOUS CONTROL FANUC CONTROL MOTOR AMPLIFIER Alpha series DESCRIPTIONS B-65162EN 11.7 SPINDLE SYNCHRONOUS CONTROL FANUC AC SPINDLE MOTOR Alpha series PARAMETER MANUAL B-65160EN 2.5 SPINDLE S