The warning message for expiration of the service lifetime Additional Manual Page 1

Additional Manual
EDT.
A
PPROVAL
DESIGN
PAGE
TITLE
No.
1
DATE
DESIGN
DESCRIPTION
DATE
The warning message for the expiration of
the service lifetime.
A
-63518
DS0100-04
/
             
                          
             Contents
1.General・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・
2
2.Specification・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・
3
2.1 
  
 Periodic Maintenance expiration message・・・
・・・・・・
・・・3
2.2 
  
 Periodic Maintenance expiration signal ・・・・
・・・・・・・・
・・・・4
3.Signal・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・
5
4.Parameter・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・
6
FS16i18 i21i
The warning message for expiration of
the service lifetime
Specifications

Contents Summary of The warning message for expiration of the service lifetime Additional Manual

  • Page 1FS16i/18 i/21i The warning message for expiration of the service lifetime Specifications Contents ・・・・・・・・・・・・・・・・・・・・ 2 1.General・・・・・・・・・・・・・・・・・・・・ ・・・・・・・・・・・・・・・・・・ 3 2.Specification・・・・・・・・・・・・・・・・・・ Periodic Maintenance expiration message・・・ 2.1 ・・・3 ・・・ Periodic Maintenance expiration signal
  • Page 21. General This function shows an warning message in the status line of the screen, when the service lifetime of the consumables registered in the periodic maintnence screen has expired. The warning message for the expiration of TITLE the service lifetime. No. A-63518 EDT. DATE DESIGN DESCRIPTION PA
  • Page 32. Specification This function indicates that such a maintenance as replacing the consumables is required by showing an warning message and outputting the service liftime expiration signal, when the service lifetime of the consumables (backup battery, LCD backlight. Toich pannel, etc)registered in t
  • Page 42.2 Periodic Maintenance expiration signal The service lifetime expiration signal LIFOVR is set to ”1” when the lifetime of one or more consumables registerd in the periodic maintenance screen has expired. The signal becomes “0” by setting the data of the expired items in the periodic maintenance sc
  • Page 53.Signal 3. ◎the ◎ output signal CNC→PMC PMC ADDRESS #7 #6 #5 #4 #3 #2 #1 #0 F0093 LIFOVR Name LIFOVR periodic maintenance expiration signal Details [CLASSIFICATION]OUTPUT SIGNAL [FUNCTION] The service lifetime expiration signal LIFOVR is set to ”1” when the lifetime of one or more consumables regis
  • Page 64. Parameter Parameter #7 #6 #5 #4 #3 #2 #1 #0 8903 PRMSG Data type: Bit PRMSG service lifetime expiration message is 0: disabled 1: enabled Parameter #7 #6 #5 #4 #3 #2 #1 #0 8901 MENTE Data type : Bit MENTE periodic maintenance screen is 0: enabled 1: disabled Parameter 8911 Ratio of the items on p