A-79345E
Title
Draw
No.
Ed. Date Design Description
Date Jan.06.’04 Design. Apprv.
20/27
page
FANUC Series 30i-MODEL A
Tool management extension function
Input to and output from an external device
Input to and output from an external device is enabled only on the ALL IO screen, the tool
management screen, or the cartridge screen.
・Input/output using the ALL IO screen
By pressing the [ALL I/O] soft key on the <SYSTEM> screen, ALL IO screen is displayed.
The screen is displayed by pressing the continuous menu key several times.
With the [DSP-LAYOUT] soft key, screen customize data can be input/output.
With the [SPWP-NAME] soft key, spindle position/standby position name data can be
input/output.
With the [CSTM-DPOINT] soft key, the decimal point position data of customize data can be
input/output.
・Input/output using the tool management screen and the cartridge screen
By pressing the <OFFSET/SETTING> key, the tool management screen or the cartridge
screen is displayed. By pressing [(OPRT)] soft key, select [READ] or [PUNCH]. By
pressing the continuous menu key several times, the same soft keys as used for input/output
on the ALL IO screen are displayed.
When data is output to an external device, the data is output in the corresponding G10 format.
Data is output under the following file names:
‘DISPCSTM.TXT’
Screen customize data
‘POSNAME.TXT’
Spindle/standby position name data
‘POINTPOS.TXT’
Customize data decimal point position