4. DESCRIPTION OF PARAMETERS
B–63180EN/02
150
6181 First–stage rapid traverse servo loop gain
6182 Second–stage rapid traverse servo loop gain
6183 Third–stage rapid traverse servo loop gain
6184 Fourth–stage rapid traverse servo loop gain
6185 Fifth–stage rapid traverse servo loop gain
6186 Third–stage rapid traverse servo loop gain
6187 Seventh–stage rapid traverse servo loop gain
[Data type] Word axis
[Unit of data] 0.01 sec
–1
[Valid data range] 1 to 9999
Seventh–stage rapid traverse servo loop gain
If a specified value is 0, parameter No. 1825 is used as a servo loop gain.
6191 Time constant T
2
for bell–shaped acceleration/deceleration for first–stage rapid
traverse during positioning by optimum acceleration
6192 Time constant T
2
for bell–shaped acceleration/deceleration for second–stage
rapid traverse during positioning by optimum acceleration
6193 Time constant T
2
for bell–shaped acceleration/deceleration for third–stage rapid
traverse during positioning by optimum acceleration
6194 Time constant T
2
for bell–shaped acceleration/deceleration for fourth–stage
rapid traverse during positioning by optimum acceleration
6195 Time constant T
2
for bell–shaped acceleration/deceleration for fifth–stage rapid
traverse during positioning by optimum acceleration
6196 Time constant T
2
for bell–shaped acceleration/deceleration for sixth–stage rapid
traverse during positioning by optimum acceleration
6197 Time constant T
2
for bell–shaped acceleration/deceleration for seventh–stage
rapid traverse during positioning by optimum acceleration
[Data type] Word axis
[Unit of data] msec
[Valid data range] 8 to 512
These parameters set time constant T
2
for bell–shaped acceleration/
deceleration for the rapid traverse in each stage of positioning by optimum
acceleration for each axis.