2005/08/29
Edit
7/8
Data Si
nature
Descri
tion
FS16i/18i/21i-MB, 18i-MB5
Retraction for 3-dimentional rigid tapping
Specifications
A-90190EN
Drawing No.
Title
Page
5 Parameter
#7 #6 #5 #4 #3 #2 #1 #0
5200 DOV
[Data type] Bit
DOV For tool retraction during rigid tapping, the override is
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
5202 RG3
[Data type] Bit
RG3 Rigid tapping retraction during 3-dimensional coordinate conversion mode or tilted
working plane command mode is performed using
0: Input signal RTNT <G062#6>.
1: G30 program command.
5381 Override for rigid tapping retraction
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 200
Sets an override value to be applied to rigid tapping retraction. No override is
applied if 0 is set to this parameter.
5382 Retract value α for rigid tapping retraction
[Data type] 2 word
[Unit of data] Input unit
[Valid data range] 0 to 99999999
Sets an extra retract value for rigid tapping retraction. The tool will be pulled beyond
the R point by α. If rigid tapping retraction has already been completed, the tool is
pulled by α only.
ote
When this parameter is set, the CNC power must be turned off before
operation is continued.
ote
This parameter is enabled when the parameter DOV (No.5200#4) is
set to “1”.