B–63523EN–1/03
9. SPINDLE SPEED FUNCTION
1114
SWS3 1 : Outputs a speed command to the third spindle.
0 : Outputs no speed command to the third spindle.
SWS4 1 : Outputs a speed command to the fourth spindle.
0 : Outputs no speed command to the fourth spindle.
[Classification] Input signal
[Function] Effective only to multi-spindle, each spindle can be stopped by this signal.
*SSTP1 1 : Does not set 0 min
–1
for output to the first spindle.
0 : Sets 0 min
–1
for output to the first spindle.
*SSTP2 1 : Does not set 0 min
–1
for output to the second spindle.
0 : Sets 0 min
–1
for output to the second spindle.
*SSTP3 1 : Does not set 0 min
–1
for output to the third spindle.
0 : Sets 0 min
–1
for output to the third spindle.
*SSTP4 1 : Does not set 0 min
–1
for output to the fourth spindle.
0 : Sets 0 min
–1
for output to the fourth spindle.
[Classification] Input signal
[Function] Gear selection signals for second to fourth spindle when multi–spindle is
equipped (2–stage). Use GR1 and GR2 <G028#1, #2> for the 1st spindle
and up to 4–stage gears can be used.
GR21 1 : Selects the second-stage gear for the second spindle.
0 : Selects the first-stage gear for the second spindle.
GR31 1 : Selects the second-stage gear for the third spindle.
0 : Selects the first-stage gear for the third spindle.
GR41 1 : Selects the second-stage gear for the fourth spindle.
0 : Selects the first-stage gear for the fourth spindle.
Individual spindle stop
signal *SSTP1, *SSTP2,
*SSTP3, SSTP4 <G027#3,
#4, #5>, <G026#6>
Gear select signal
GR21 <G029#0>
GR31 <G029#2>
GR41 <G031#4>