B–63523EN–1/03
1. AXIS CONTROL
197
(Example 1) Synchronizing the Z
2
–axis with the Z
1
–axis
Path 1 Path 2
Parameter No. 8180x 0 Parameter No. 8180x 0
Parameter No. 8180z 0 Parameter No. 8180z 2
Parameter No. 8180c 0 Parameter No. 8180c 0
Parameter No. 8180y 0 Parameter No. 8180y 0
S Exercising synchronous control in a path
In the parameter of a slave axis , specify 200 plus the number of the
master axis with which the slave axis is to be synchronized.
Setting: 201 to 208
The value specified here must not exceed 200 plus the maximum
number of control axes.
(Example 1) Synchronizing the Y
1
–axis with the Z
1
–axis
Path 1 Path 2
Parameter No. 8180x 0 Parameter No. 8180x 0
Parameter No. 8180z 0 Parameter No. 8180z 0
Parameter No. 8180c 0 Parameter No. 8180c 0
Parameter No. 8180y 202 Parameter No. 8180y 0
8181 Synchronization error limit of each axis (Synchronous or composite control)
[Data type] Two–word axis
[Unit of data] Unit of detection
[Valid data range] 0 to 32767
When the synchronization deviation detected (SERx of Bit #1 parameter
No. 8162 is set to 1), this parameter specifies the limit of the difference
between the positioning deviation of the slave axis and that of the master
axis. Set this parameter for the slave axis.
8182 Display of the synchronization error of an axis (synchronous or composite control)
[Data type] Two–word axis
[Unit of data] Unit of detection
[Valid data range] 0 or more
When the synchronization deviation is detected (SERx of Bit #1
parameter No. 8162 is set to 1), this parameter specifies the difference
between the positioning deviation of the slave axis and that of the master
axis. (The value is used for diagnosis.) The deviation is displayed on the
slave side
The parameter is only for the display.
The difference between the positioning deviation is:
(Positioning deviation of the master axis) " (Positioning deviation of the slave axis)
Plus for a mirror–image synchronization
command
Minus for a simple synchronization
command