Contents Summary of FANUC Series 16/18 MC 16i/18i MA toollife management b Additional Manual
Page 1FANUC Series 16/18-MC FANUC Series 16i/18i-MA Tool Life Management B Specifications Software Software Software Laboratory Laboratory FLB1 Section FLB1 Section Title FS16/18-MC , FS16i/18i-MA Tool Life Management B Drawing No. A-63526E ページ Edit Data Signature Description 0/13 1998/09/21 DS0000-00 1版
Page 2FANUC Series 16/18-MC FANUC Series 16i/18i-MA Tool Life Management B Specifications 1.TOOL LIFE VALUE EXPANSION (999999TIMES/100000MINUTES) ........................................... 2 1.1. GENERAL .....................................................................................................
Page 31. Tool life value expansion (999999 999999times/100000 999999 /100000minutes) /100000 ) 1.1.General Though the maximum value of the tool life could be set 65535 times or 4300 minutes by the tool life management, the value is possible to expand for 999999 times or 100000 minutes by using the option
Page 42. Arbitrary tool group number setting 2.1.General By using this function (parameter No.6802#5), it is possible to specify the group by using an arbitrary T code instead of the group by using T code of tool life management ignore No. + Group No. 2.2.Setting method (1)The data setting by programming
Page 5Note 1) If the arbitrary group number is set to the same number at other groups, PS158 alarm is generated. Note 2) Please set arbitrary group number (1-99999999). If the arbitrary group number is not set, PS149 alarm is generated. Note 3) It is not possible to set to the arbitrary group number by ex
Page 62.3. Use method The arbitrary group number is specified same as usual tool life management with T code. But tool life management ignore number (parameter No.6810) cannot be used. Example) When tool of the group is used after arbitrary group number 12345 is set to group No. 1 O0001; T12345; → tool se
Page 73. Tool life notice signal 3.1.General When‘Tool life value(LIFE)-life counter value(COUNT)' reaches the value that is the remainder of tool life until selecting a new tool for each groups, signal (TLCHB) is output to PMC. 3.2.Setting method The remainder of tool life until selecting a new tool (rem
Page 8(2)The data setting by extended tool life management (data editing screen for the group). It is possible to edit the remaining tool life by using the extended tool life management (data editing screen for the group). The edit method is done by the same method as other items. That is, The cursor is m
Page 93.3. Use method When the tool counter is added 1 and ‘Tool life value (LIFE)-life counter value (COUNT)' reaches the value (remaining tool life value), signal (TLCHB) is output to PMC. Example) It is assumed that group No. 1 is in the state when life is controlled by the frequency as follows. EDIT L
Page 103.4.Note Note 1) The parameter of the extended tool life management is necessary. Note 2) The signal is turned on as follows. (1) When value of‘LIFE-COUNT' and value of remaining tool life of each group is the same. → "Equal" type (2) When value of‘LIFE-COUNT' is smaller than value of remaining tool
Page 113.5. Parameter data No. #7 #6 #5 #4 #3 #2 #1 #0 6802 RMT ARL GRP GRP Data for the notice signal (TLCHB)is used by 0 : parameter No.6844,No.6845 1: data to be set for each group ARL The notice signal (TLCHB) is 0: output each tool 1: output last tool in the group Note)This parameter is effective when
Page 124. Display The group number is displayed 8 digits, the count and life data number is displayed 6 digits in the tool life screen and extended tool life screen. 【tool life management display】 TOOL LIFE DATA : O0001 N00000 NXT 99999999 USE 00000001 SLCT 00000001 001: 00000001:C LIFE 100000 COUNT 100000
Page 145. Comparisons between Tool Life Management and Tool Life Management B Tool life management B is upper compatible with tool life management. function tool life tool life note management B management extended tool life management 〇 〇 6801#6 tool life count override 〇 〇 6801#2 life count by 1 sec 〇 〇