ページ
ページ
ページ
ページ
4
13
Si
nature Description
1998/09/21
FS16/18-MC , FS16i
18i-M
Tool Life Management B
A-63526E
Title
Drawin
No.
Edit Data
Note 1) If the arbitrary group number is set to the same number at other groups, PS158
alarm is generated.
Note 2) Please set arbitrary group number (1-99999999). If the arbitrary group number is
not set, PS149 alarm is generated.
Note 3) It is not possible to set to the arbitrary group number by exceeding eight digits.
If the arbitrary group number by exceeding eight digits is set, PS003 alarm is
generated.
Note 4) If the decimal point is set in the arbitrary group number, PS007 alarm is generated.
And if the sign is set in the arbitrary group number, PS006 alarm is generated.
Note 5) Please the number of permissible digits of T codes (parameter No.3032) to eight
digits.
(2)The data setting by extended tool life management (data editing screen for the group).
It is possible to edit the arbitrary group number by using the extended tool life management
(data editing screen for the group).
The edit method is done by the same method as other items. That is,
The cursor is matched to the arbitrary group number.
↓
The numerical value is input.
↓
The soft key [INPUT] is pushed.
Note 1) The arbitrary group number is possible to edit as other items.
Note 2) If the same number already exists when an arbitrary number is set, a warning is
generated.
Note 3) The value of the group cannot be set by exceeding maximum value (99999999). If
the value is set, a warning is generated.