ページ
ページ
ページ
ページ
7
13
Si
nature Description
1998/09/21
FS16/18-MC , FS16i
18i-M
Tool Life Management B
A-63526E
Title
Drawin
No.
Edit Data
(2)The data setting by extended tool life management (data editing screen for the group).
It is possible to edit the remaining tool life by using the extended tool life management (data
editing screen for the group).
The edit method is done by the same method as other items. That is,
The cursor is matched to the arbitrary group number.
↓
The numerical value is input.
↓
The soft key [INPUT] is pushed.
Note 1) The remaining tool life data is possible to edit as other items.
Note 2) Please set the life value, the life counter, and the remaining tool life value again
when the life count type is changed.
Note 3) When the life counter is added 1 if the remaining tool life value is set larger than
the value of “life value-life counter” , signal (TLCHB) is output to PMC.
Note 4) The life value cannot be set smaller value than the remaining tool life value. If
that value is set, warning of“The data is outside the range" is generated.
Therefore, please confirm the remaining tool life value when the life value is set
smaller than now.
Note 5) The remaining tool life value cannot be set larger value than the life value. If
that value is set, warning of “The data is outside the range" is generated.