Dra
No.
Title
SheetDescri
tionDesi
n Date Edit
FANUC Pulse Input Type
Digital Servo Adapter
Connection Manual (Hardware)
A-77226EN
/
53
7.2.2 Connection of Power supply
Power of the separate detector interface unit should be supplied
from an external 24 VDC power supply. To the extended unit, if it
exists, power is supplied from the basic unit.
CP11A
Cable
CP11A
AMP JAPAN
1-178288-3 (Housing)
1-175218-5 (Contact)
Separate detector interface unit (basic)
External power supply
24 VDC regulated
power supply
24 VDC±10%
+24V (1)
0V (2)
0V
1
3
+24V
2
External power supply
Recommended cable specification: A02B-0124-K830(5m)
(The external power supply end of the cable is provided with M3 crimp terminals.)
Select a connector
that matches the pin
layout of the external
power supply
GND
The 24 VDC input to CP11A can be output at CP11B for use in
branching.
The connection of CP11B is identical to that of CP11A. In this case,
the power supplied to CP11A should be equal to the sum of the
rating of the separate detector interface unit and that of the units
after CP11B.
Be sure to ground the 0V line of the power supply to the separate
detector interface unit. In addition, keep any noise source (such as
an AC power cable and contactor) away from the power line of the
separate detector interface unit as far as possible to prevent noise
from being picked up through the power line.
Secure the ground line to the ground terminal (GND) for signals of
a separate detector interface unit, which is located at the bottom of
the unit, with an M3 screw as shown in the figure below. Connect
the ground line to the ground plate of the cabinet.