5.3.4 FSSB connection
(1) Case of one FSSB path
All axes connected with one FSSB path require setting to the same HRV control. Therefore, if Learning
HRV3 control is applied in one axis at least, other all axes require Servo HRV3 control.
(2) Case of two FSSB paths
Even if two FSSB path is used, all axes connected with each FSSB path require setting to the same HRV
control. Therefore, if Learning HRV3 control is applied in one axis at least, other all axes that include
another FSSB path require Servo HRV3 control.
If Learning axis is full-closed system, outer detection I/F unit must be connected with the same path as
Learning axis.
There is the following restriction with regard to the possible number of unit connecting with the same FSSB
path.
Control Maximum number of Amplifier / Outer detection unit
HRV2 16 / 2
HRV3 10 / 2
HRV4 4 / 1
Servo axis
control card
Servo Amplifier
HRV3
Servo Amplifier
Learnin
HRV3
Servo Amplifier
HRV3
Outer detect I/F
unit
HRV3
Servo axis
control card
Servo Amplifier
Learnin
HRV3
Servo Amplifier
HRV3
Servo Amplifier
HRV3
Outer detect I/F
Unit
HRV3
Servo axis
control card
Servo Amplifier
Leanin
HRV3
Servo Amplifier
HRV3
Servo Amplifier
HRV3
Outer detect I/F
unit
HRV3