12
FANUC Series 16i /18i -MA
Spindle electronic gear box
S
ecifications
EDT. DATE DESIG. DESCRIPTION PAGE /19
A – 77833E
NO.
TITLE
NEWLY
1999.July.28
01
5) In case that the parameters for axis setting (No.7710,7771,4352) are not
set correctly, P/S alarm (No.010) occurs when G81 specified.
6) When G28/G27/G29G30/G30.1/G53 is specified in the synchronization
mode, P/S alarm (No.184) occurs. G28/G27/G29/G30/G30.1/G53 should
not be specified in the synchronization mode.
7) During HPCC mode with RISC, the high-speed cycle cutting, the high-speed
liner interpolation, the high-speed remote buffer A, the high-speed remote
buffer B of DNC operation, and AI contour control, this function is not available.
8) The slave axis position display is updated by synchronous pulse as follows :
- Machine position display is updated.
- Absolute position display and relative position display are not updated. When
the synchronization is canceled, the pulses of the synchronization are added
to the absolute position display of the slave axis.
9) The rotation direction of the workpiece axis depends on the rotation
direction of the tool axis. That is, when the rotation direction of the tool axis
is positive, the rotation direction of the workpiece axis is also positive; when
the rotation direction of the tool axis is negative, the rotation direction of the
workpiece axis is also negative. However, by specifying a negative value for
L, the rotation direction of the workpiece axis can be made opposite to the
rotation direction of the tool axis.
10) During synchronization, a move command can be programmed for the workpiece
axis. Note, however, that incremental command programming for cutting feed
must be used to specify the workpiece axis move command.
11) The synchronization mode is canceled by servo alarm, spindle alarm, P/S alarm
(No.000), or emergency stop.
12) The synchronization is not maintained in servo off status of the slave axis.
13) When the EGB control is used, the drilling canned cycle cannot be used.
14) The actual feedrate is displayed without the flexible synchronous pulse.