3. Parameters
3.1 Parameters for serial spindle
[Data type] Word
[Valid data range] 0 to 10000
Feed forward coefficient for Cs contour control axis is set.
Specified value is smaller than or equal to 100 : In units of 1%
Specified value is greater than 100 : In units of 0.01%
[Data type] Bit
SPEGBS The spindle EGB function for slave spindle is:
0 : Disabled.
1 : Enabled.
SPEGBM The spindle EGB function for master spindle is:
0 : Disabled.
1 : Enabled.
[Data type] Word
[Valid data range] 64 to 4096
Specify the number of sinusoidal waves per spindle 1 rev. from the master
spindle position detector.
This parameter should be set to the slave spindle amplifier.
Setting this parameter to 0 is equivalent to the synchronous ratio 0.
4352
4386
Number of sinusoidal waves from master spindle position detector
4036
Feed forward coefficient for serial spindle
SPEGBM SPEGBS
76543210