FANUC Series 16i/18i -MA
SPECIFICATIONS FOR
ELECTRONIC GEAR BOX
AUTOMATIC PHASE SYNCHRONIZATION
EDT. DATE DESIG.
DESCRIPTION
PAGE
10 / 14
A – 77934E
NO.
TITLE
01
1999.OCT.29
NEWLY
3. Parameters
#7 #6 #5 #4 #3 #2 #1 #0
7702 PHD PHS
[Data type] Bit
PHS Specifies whether to perform acceleration/deceleration when EGB
synchronization is started or canceled if there is no R
command in a G81/G80 block.
0: Do not perform acceleration/deceleration when EGB
synchronization is started or canceled.
1: Perform acceleration/deceleration when EGB
synchronization when EGB synchronization is started or
canceled, and automatically perform phase
synchronization after acceleration when synchronization
starts.
PHD Specifies the direction of movement for automatic phase
synchronization.
0: Positive (+) direction
1: Negative (-) direction
[Data type] 2 Words
[Valid data range] 0 to 24000
[Unit of data]
Increment system Unit of data
IS-B IS-C
Deg/min 10.0
1.0
When the setting value of this parameter is 0, as for the speed,
the rapid speed (Parameter No.1420) is used.
[Data type] 2 Words
[Unit of data]
Increment system Unit of data
IS-B IS-C
Rotation axis 0.001deg 0.0001deg
[valid data range] : 0 to 3600000
Angle deviation from the spindle position (position of the one-rotation
signal) used as a reference for workpiece-axis phase synchronization
7776 S
eed for work
iece-axis automatic
hase s
nchronization
7777