FANUC Series 16i/18i -MA
SPECIFICATIONS FOR
ELECTRONIC GEAR BOX
AUTOMATIC PHASE SYNCHRONIZATION
EDT. DATE DESIG.
DESCRIPTION
PAGE
14 / 14
A – 77934E
NO.
TITLE
01
1999.OCT.29
NEWLY
4. Signals
7 6 5 4 3 2 1 0
SYNMOD
Synchronization mode signal SYNMOD
[Classification] Output signal
[Function] Confirmation of the EGB synchronization
[Operation] The signal becomes “1” when :
: The EGB synchronization is active.
The signal becomes “0” when :
: The EGB synchronization is canceled.
5. Alarm and Message
Number Message Contents
181 EGB AUTO PHASE
FORMAT ERROR
Format error in block in which G80 or G81
was specified by EGB automatic phase
synchronization
(1) R is data outside of the instruction
range.
(2) Before the G81R2 command, the master
spindle isn't returned to in the reference
point. (In case of Spindle EGB)
F065