Edit
10/11
FANUC Series 16i/18i-MA
FANUC Series 16i/18i-TA
Bidirectional pitch error compensation
A-77810E
Drawing No.
Title
Page
02 99/07/19 N.Aizawa Modified
a
e10-14
03 00/04/28
Added T series, Modified page10
Date Design
Descri
tion
Date
1999/06/23
Design
N.Aizawa
Approv
E.Genma
NOTE
When this parameter is set, the power must be turned off before
operation is continued.
6. Setting and displaying data
All the compensation data can be displayed and set on the conventional screen for the
pitch error compensation data.
And those data can be input and output by the following methods.
* Input by MDI
* Input by G10
* Input and output by input/output device interface
* Input by PMC window (function code 18)
(It is not possible to input and output by the method other than the above
methods.)
Output format : The output format is as follows:
N20000 P…. ;
N21023 P…. ;
N23000 P…. ;
N24023 P…. ;
N : Pitch error compensation point No. + 20000
P : Pitch error compensation data
7. Note
(1) To use this function, the stored pitch error compensation option is required.
(2) This function is enabled after a manual reference position return or an automatic
reference position return with the same sequence as that of a manual reference
position return is performed. When an absolute position detector is used, however,
the function is enabled after the power is turned on.
(3) When the machine moves to the reference position in the reference position return
direction, set the absolute value of the pitch error compensation pulse to 0.
(4) When this function and backlash compensation are used at the same time, the pulse
resulting from backlash compensation is superimposed on the compensation pulse
when the travel direction is reversed.
(5) When this function is used for a rotation axis, the sum of the pitch error compensation
amounts per rotation about the rotation axis must be 0 for both the positive and
negative directions.
(6) The function cannot be used with the inclination compensation function.