Improvement of Rigid Tapping Additional Manual Page 1

Additional Manual
EDT
DATE
A-61050E
1 / 3
DS0100-04
01
2001.Mar.23
Newly registered
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
FANUC Series 16/18
i
-MA, 16/18-MC
Improvement of rigid tapping function
Specifications


Table of contents


1. General 

2
2. Specification 

3
3. Parameters 

3
Copyright © 2001 FANUC LTD. All rights reserved.
FANUC Series 16/18
i
-MA
FANUC Series 16/18-MC
Improvement of rigid tapping function
Specifications
This specifications may be modified for improvement without notice.

Contents Summary of Improvement of Rigid Tapping Additional Manual

  • Page 1FANUC Series 16/18i-MA FANUC Series 16/18-MC Improvement of rigid tapping function Specifications Table  of contents 1. General 2  2. Specification 3  3. Parameters 3  This specifications may be modified for improvement without notice. Co
  • Page 21. General In this function, the feed-forward control and the fine acceleration/deceleration at the rigid tapping have been improved, and setting the width of in-position in R-point has been improved. 2. Specification (1) When parameter RFF (No.5203#2) is set to "1", the feed-forward control and the
  • Page 33. Parameters No. #7 #6 #5 #4 #3 #2 #1 #0 5203 REF [Data type] Bit REF The operation of the rigid tapping is as shown in the following setting. 1 : The feed-forward control and the fine acceleration/deceleration between Initial-level and R-points are effective. Moreover, when the rigid tapping is ex