Correction of Parameter No.1850 (Grid Shift for Each Axis) Description, FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Supplement to Manual Page 1

Supplement to Manual
Sheet
Title
Draw
No.
Ed. Date Design Description
Date Aug.05.05 Desig. Apprv.
1/2
FANUC Series 0i - C, 16i/18i - A/B
Parameter Manual
Correction of parameter No.1850 description
B-64120EN/01-01 B-63530EN/03-01
B-63010EN/02-06
FANUC Series 0i/0i Mate - MODEL C Parameter Manual
FANUC Series 16i/18i/160i/180i/160is/180is - MODEL A Parameter Manual
FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual
Correction of parameter No.1850 (Grid shift for each axis) description
1.Type of applied technical documents
Name
FANUC Series 0i/0i Mate - MODEL C Parameter Manual
FANUC Series 16i/18i/160i/180i/160is/180is - MODEL A Parameter Manual
FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual
Spec.No./Ed.
B-64120EN/01 , B-63530EN/03 , B-63010EN/02
2.Summary of Change
Group Name/Outline
New, Add,
Correct,
Delete
Applicable
Date
Basic
Optional
Function
Unit
Maintenance
Parts
Notice
Correction The description of parameter No.1850 (Grid shift for each axis) is corrected.
Another

Contents Summary of Correction of Parameter No.1850 (Grid Shift for Each Axis) Description, FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Supplement to Manual

  • Page 1FANUC Series 0i/0i Mate - MODEL C Parameter Manual FANUC Series 16i/18i/160i/180i/160is/180is - MODEL A Parameter Manual FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Correction of parameter No.1850 (Grid shift for each axis) description 1.Type of applied technical documents
  • Page 2Outline The data setting range of parameter No.1850 (Grid shift for each axis) is corrected. Detail The data setting range of parameter No.1850 (Grid shift for each axis) is corrected as follows. Before correction ) [Valid data range] 0 to 99999999 (for reference position shiht) Reference counter si