Correction of Parameter No.1850 (Grid Shift for Each Axis) Description, FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Supplement to Manual Page 2

Supplement to Manual
Sheet
Title
Draw
No.
Ed. Date Design Description
Date Aug.05.05 Desig. Apprv.
2/2
FANUC Series 0i - C, 16i/18i - A/B
Parameter Manual
Correction of parameter No.1850 description
B-64120EN/01-01 B-63530EN/03-01
B-63010EN/02-06
Outline
The data setting range of parameter No.1850 (Grid shift for each axis) is corrected.
Detail
The data setting range of parameter No.1850 (Grid shift for each axis) is corrected as follows.
Before correction )
[Valid data range] 0 to 99999999 (for reference position shiht)
Reference counter size or less (for grid shift)
To shift the reference position, the grid can be shifted by the amount set in
this parameter.
Up to the maximum value counted by the reference counter can be specified
as the grid shift.
In case of parameter SFD (No.1002#2) is 0: Grid shift
In case of parameter SFD (No.1002#2) is 1: Reference position shift
After correction )
[Valid data range] 0 to 99999999 (for reference position shiht)
( - Reference counter value ) to ( + Reference counter value )
(for grid shift)
To shift the reference position, the grid shift value or reference position shift
value is set in this parameter for each axis.
Up to the maximum value
counted by the reference counter can be specified
as the grid shift.
In case of parameter SFD (No.1002#2) is 0: Grid shift
In case of parameter SFD (No.1002#2) is 1: Reference position shift

Contents Summary of Correction of Parameter No.1850 (Grid Shift for Each Axis) Description, FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Supplement to Manual

  • Page 1FANUC Series 0i/0i Mate - MODEL C Parameter Manual FANUC Series 16i/18i/160i/180i/160is/180is - MODEL A Parameter Manual FANUC Series 16i/18i/160i/180i/160is/180is - MODEL B Parameter Manual Correction of parameter No.1850 (Grid shift for each axis) description 1.Type of applied technical documents
  • Page 2Outline The data setting range of parameter No.1850 (Grid shift for each axis) is corrected. Detail The data setting range of parameter No.1850 (Grid shift for each axis) is corrected as follows. Before correction ) [Valid data range] 0 to 99999999 (for reference position shiht) Reference counter si