FANUC LTD
ED
FANUC Series 16i-MA
SYNCHRONOUS CONTROL BETWEEN 2 PATH
01
TAKEUCHI
TAKEUCHI
5.4 State signal of axes during synchronous controls
State signal During synchronous control
Movement state
signal
MVn F0102/F1102
The signal of the master axis
becomes "1" while the master axis or
the slave axis is moving.
Signal of slave axis is always "0". (1)
Movement direction
signal
MVDn F0106/F1106
Signal of the master axis is a direction
of the movement of the master axis.
Signal of the slave axis is a direction of
the movement after mirror image
processing of the synchronous.
In-position signal
INPn F0104/F1104
Signal of the master axis becomes "1"
while both the master axis and the
slave axis and are in-position state.
Signal of the slave axis is always "1".
(1) In the check on position deviation, parameter No.1828 is used as a limit
value if movement pulse is commanded to the motor (regardless of the master
or slave), parameter No.1829 is used if any movement pulse is not commanded.
It does not depend on the state of this signal.