1. OUTLINE
This document describes the way of measure when the ladder graphic display is not good on the
monochrome LCD of Power Mate-MODEL D/H and applied software series and editions.
2. Applied software
Power Mate–MODEL D
Software Series Edition
Power Mate-MODEL D(1path
8838 01() or later
Power Mate-MODEL D(2path
8839 01() or later
Power Mate-MODEL H
Software Series Edition
PMC-PA3 control software
4078 05() or later
Ladder editing card 4079 02() or later
3. Setting in case of using the monochrome LCD
If the ladder diagram display is not good on the monochrome LCD , please set bellow:
Set the bit 3 of keep relay K19 to "1" , and turn off and on the power supply.
#7 #6 #5 #4 #3 #2 #1 #0
K19
LCD-MONO
#3 LCD-MONO 0 : It is displayed by the difference of the brightness on the
monochrome
LCD.
1 : It is displayed by the reverse display on the monochrome LCD.
Note
Ladder editing card can not be used.
Note
This parameter becomes effective at the next power on after the
setting is changed.
Please turn off and on the power supply again after you change
the parameter setting.

Contents Summary of FANUC Power Mate-D/H The way of measure when the ladder graphic display is not good on the monochrome LCD Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) No.TMN99/045E Date 1999. General Manager of Software Laboratory FANUC Power Mate-D/H The way of measure when the ladder graphic display is not good on the monochrome LCD 1.Communicate this report to : ○ Your information ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MIL
  • Page 21. OUTLINE This document describes the way of measure when the ladder graphic display is not good on the monochrome LCD of Power Mate-MODEL D/H and applied software series and editions. 2. Applied software ・Power Mate–MODEL D Software Series Edition Power Mate-MODEL D(1path) 8838 01(A) or later Powe
  • Page 3You can use the setting parameter display for above mentioned change. PMC PRM (SETTING) MONIT RUN PROGRAMMER ENABLE = 0(0:NO 1:YES) (K17.1) LADDER START = 0(0:AUTO 1:MANUAL) (K17.2) RAM WRITE ENABLE = 0(0:NO 1:YES) (K17.4) SIGNAL TRACE START = 0(0:MANUAL 1:AUTO) (K17.5) DATA TBL CNTL SCREEN= 0(0:YES