Edit Date
Design
FANUC Power Mate-MODEL D/H
The way of PMC’s measure on the
monochrome LCD
A-77761E
Page3/3
Description
Title
Draw
You can use the setting parameter display for above mentioned change.
GRAY SCALE DISPLAY
This is a way of setting the ladder graphic display on the monochrome LCD.
If the display on the monochrome LCD is not good , then please change the setting.
If “USE” is selected, it is displayed by the difference of the brightness.
If “UNUSED” is selected, it is displayed by the reverse display.
PMC PRM (SETTING) MONIT RUN
PROGRAMMER ENABLE = 0(0:NO 1:YES)
(K17.1)
LADDER START = 0(0:AUTO 1:MANUAL)
(K17.2)
RAM WRITE ENABLE = 0(0:NO 1:YES)
(K17.4)
SIGNAL TRACE START = 0(0:MANUAL 1:AUTO)
(K17.5)
DATA TBL CNTL SCREEN= 0(0:YES 1:NO)
(K17.7)
SIGNAL TRIGGER START= 0(0:MANUAL 1:AUTO)
(K18.2)
GRAY SCALE DISPLAY = 0(0:USE 1:UNUSED)
(K19.3)
Note
This parameter becomes effective at the next power on after the
setting is changed.
Please turn off and on the power supply again after you change
the parameter setting.