A-79969E
Format
L_ Maa (Dbbb) (Mcc) (Dddd) (Mee) (Dfff);
L : Table time for M codes effect
Maa : First M-code
Mcc : Second M-code
Mee : Third M-code
Dbbb : Delay time corresponding to Maa (msec)
Dddd : Delay time corresponding to Mcc (msec)
Dfff : Delay time corresponding to Mee (msec)
Range of D command : 0 and 4 or 8-32760
Mcc, Mee and D_ can be omitted.
Note
When M code is output and the ladder of the PMC does not execute
the completion processing of the previous M code, PS alarm (No.451) is
generated.
Note
The ladder sequence of the PMC follows the specification of multiple
M commands in a single block when using second M-code and third
M-code.
Refer to the connection manual (function) "10.3 Multiple M commands
in a single block" about details.
(2
Sheet
Title
Draw
No.
02 Oct. 22.'05 Addition or Modification of (2.
Ed. Date Design Description
Date Jan.31.’05 Desig. T.Watanabe Apprv. Y.Takeuchi
FANUC Series 30i/31i
Specifications of
Auxiliary function table with delay time
3/12