A-79969E
Sheet
Title
Draw
No.
02 Oct. 22.'05 Addition or Modification of (2.
Ed. Date Design Description
Date Jan.31.’05 Desig. T.Watanabe Apprv. Y.Takeuchi
FANUC Series 30i/31i
Specifications of
Auxiliary function table with delay time
8/12
The limitation when increasing time reference override
When the value of time reference override signal <G0520#0 to #6> is increased,
the real time to output M codes becomes early.
Therefore, there is a possibility that the real time to output M codes becomes a
passed time.
Example 1)
Time M code Delay time
1500 [msec] 128 90 [msec]
2500
(2) OVR is increased to 100% from 50% at the table time 1100.
The real time for output of M code changes to 2100.
The real time has already passed.
(1) The first override is 50%.
M code output at table time 1250.
Real time to output M codes [msec]
Table time [msec]
3000
15001250
Delay time
OVR=50%
2600
1500
2200
1100
2100
Delay time
OVR=100% OVR=50%
(3) Clamp OVR = 100 x (1500 – 1100 ) / 500 = 80%
2700
1500
2200
1100
Delay time
OVR=80% OVR=50%
Real time to output M codes [msec]
(2
Table time [msec]
Real time to output M codes [msec]
Table time [msec]
Override Clamp
In order to keep delay time, CNC clamps actual override with the following
value.
timedelay
timetablecurrenttimetablecommand
overrideClamp
_
)____(100
(%)_
−
=