B–64113EN/01
8. CONNECTION TO FANUC I/O Link
101
The following is an example in which two operator’s panel I/O boards and
one machine operator’s panel are used.
DI space map DO space map
X4
Operator’s panel I/O Y0 Operator’s panel I/O
X5
DI 48 points
Y1
DO 32 points
S Y2
X9 Y3
X10 Reserved Y4 Operator’s panel I/O
S Reserved Y5
DO 32 points
X15 Reserved Y6
X16 First MPG Y7
X17 Second MPG Y8 Machine operator’s
X18 Third MPG Y9
panel
X19 DO alarm detection Y10
X20 Operator’s panel I/O Y11
X21
DI 48 points
Y12
S Y13
X25 Y14
X26 Reserved Y15
S Reserved
S Reserved
X34 Reserved
X35 DO alarm detection
X36 Machine operator’s
S
panel
X47
NOTE
1 Since readout from the manual pulse generator (X16 to
X18) is directly performed by the CNC, only the above
assignment must be performed by the PMC.
2 See Subsec. 9.3.8 for details on DO alarm detection (X19
and X35).
3 For the Series 0i Mate, up to 240 DI points and up to 160 DO
points can be used.