12. CUSTOMER'S BOARD MANIPULATION B-63322EN-2/01
- 54 -
•
••
• Format of parameters of type integer
N ***** P ****** ;
A number that follows letter N is a parameter number.
A number that follows letter P is the value (integer) of the parameter.
The semicolon represents an end-of-block code. (It is LF in ISO code
and CR in EIA code.)
Example
N01000P31515;
Parameter No. 1000
Parameter value 31515
•
••
• Format of parameters of type integer axis
N ***** A ** P ****** A ** P ******
... ...
;
A number that follows letter N is a parameter number.
A number that follows letter A is a controlled axis number (1 or
greater)
A number that follows letter P is the value (integer) of the parameter.
The semicolon represents an end-of-block code. (It is LF in ISO code
and CR in EIA code.)
Example
N02020A1P88A2P89A3P90A4P66......;
Parameter No. 2020
Parameter value First axis : 88
Second axis : 89
Third axis : 90
Fourth axis : 66
•
•
••
• Format of parameters of type real number
N ***** P ****** ;
A number that follows letter N is a parameter number.
A number that follows letter P is the value (real number) of the
parameter.
The semicolon represents an end-of-block code. (It is LF in ISO code
and CR in EIA code.)
Example
N03001P5000.000;
Parameter No. 3001
Parameter value 5000.000