Connection of Servo Amplifier Additional Manual Page 5

Additional Manual
TITLE
DRAW
.
No.
5 / 6
Page
FANUC LTD
DESCRIPTION DESIGN DATE
EDIT
Connection of servo amplifier βiSVSP
and power failure backup module
A
-72562-031
<4> Retention time at an instantaneous power break
30 msec or greater
* Generally, the retention time given on the catalog is the value assumed when the
load factor is 100%. If the retention time requirement of 30 msec or greater is
not satisfied, the retention time can be extended by reducing the load factor.
An example of a power supply that conforms to the above specifications is the
LDA150B-24 of COSEL Co., Ltd. (output: 150W).
Connector specification
Power source (DC24V)
of third party
CX14
Maker
Tyco Electronics AMP
Connector
specification
Please refer to specification of
maker.
D-3100 series
Hausing 1-178288-3
Contact 1-175218-1
Wire size 0.5mm
2
,
AWG20
Outer diameter
of isolated cover
1.08-2.83 mm

Contents Summary of Connection of Servo Amplifier Additional Manual

  • Page 1Connection of servo amplifier βiSVSP and power failure backup module 1. Type of applied documents Name FANUC SERVO AMPLIFIER βiSV series DESCRIPTIONS Spec. No./Ver. A-72562-031 2. Summary of Change Group Name / Outline New, Add Applicable Correct, Del Date Basic Function Optional Function Unit Maint
  • Page 2Connection of servo amplifier βiSVSP and power failure backup module 1. Overview This documents describes about the connection of βiSVSP and power failure backup module. Please also refer to DESCRIPTIONS (A-53866-464) for the details. All specifications and designs are subject to change without noti
  • Page 32. Connection diagram Connection of servo amplifier βiSVSP TITLE and power failure backup module DRAW. No. A-72562-031 EDIT DATE DESIGN DESCRIPTION FANUC LTD Page 3/6
  • Page 43. Detail of cable connection Please refer to DESCRIPTIONS (A-53866-464) except for cables below. (1) Detail of cable K94 For power source (DC24V) cable of power failure backup module Power source Power failure (DC24V) backup module of third party CX14 24V (1) 24V K94 0V (2) 0V (3) Specifications of
  • Page 5<4> Retention time at an instantaneous power break 30 msec or greater * Generally, the retention time given on the catalog is the value assumed when the load factor is 100%. If the retention time requirement of 30 msec or greater is not satisfied, the retention time can be extended by reducing the l
  • Page 6(2) Detail of cable K95 Interface cable of βiSVSP and power failure backup module SVSP JX6 JX1A (9) *CRDY (9) (12) 0V (10) Connector Example (HONDA) Connector Example (HONDA) Connector PCR-E20FA Connector PCR-E20FA Hausing PCR-V20LA Hausing PCR-V20LA Cable specification: 0.09mm2 twisted pair sealed