Connection of Servo Amplifier Additional Manual Page 6

Additional Manual
TITLE
DRAW
.
No.
6 / 6
Page
FANUC LTD
DESCRIPTION DESIGN DATE
EDIT
Connection of servo amplifier βiSVSP
and power failure backup module
A
-72562-031
(2) Detail of cable K95
Interface cable of β
iSVSP and power failure backup module
SVSP
JX6 JX1A
(9) (9)
(12) (10)
Connector Example (HONDA) Connector Example (HONDA)
Connector PCR-E20FA Connector PCR-E20FA
Hausing PCR-V20LA Hausing PCR-V20LA
Cable specification: 0.09mm
2
twisted pair sealed cable
Recommend cable (Only wire): A66L-0001-0284#10P
(3) Detail of cable K64
Cable to supply AC200V voltage or DC link voltage output from CX13 to third party power
supply. And power supply output DC24V to βiSVSP, CNC, and PMC etc.
Cable specification: Vinyl cabtyre cable: JIS C 3312 2 pieces
wire1.25mm
2
(50/0.18) Outer diameter PVC 9.6φ
Conenctor specification: Tyco Electronics AMP
Hausing: 2-178128-3CX13
1-178128-3CX1A
Contact: 1-175218-2
*CRDY
0V
(3)
(2)
(1)
200S2 (DC)
200S2 (DC)
CX13
Power source
200S
200R
DC24V
output
Power source for
βi SVSP, CNC, PMC etc

Contents Summary of Connection of Servo Amplifier Additional Manual

  • Page 1Connection of servo amplifier βiSVSP and power failure backup module 1. Type of applied documents Name FANUC SERVO AMPLIFIER βiSV series DESCRIPTIONS Spec. No./Ver. A-72562-031 2. Summary of Change Group Name / Outline New, Add Applicable Correct, Del Date Basic Function Optional Function Unit Maint
  • Page 2Connection of servo amplifier βiSVSP and power failure backup module 1. Overview This documents describes about the connection of βiSVSP and power failure backup module. Please also refer to DESCRIPTIONS (A-53866-464) for the details. All specifications and designs are subject to change without noti
  • Page 32. Connection diagram Connection of servo amplifier βiSVSP TITLE and power failure backup module DRAW. No. A-72562-031 EDIT DATE DESIGN DESCRIPTION FANUC LTD Page 3/6
  • Page 43. Detail of cable connection Please refer to DESCRIPTIONS (A-53866-464) except for cables below. (1) Detail of cable K94 For power source (DC24V) cable of power failure backup module Power source Power failure (DC24V) backup module of third party CX14 24V (1) 24V K94 0V (2) 0V (3) Specifications of
  • Page 5<4> Retention time at an instantaneous power break 30 msec or greater * Generally, the retention time given on the catalog is the value assumed when the load factor is 100%. If the retention time requirement of 30 msec or greater is not satisfied, the retention time can be extended by reducing the l
  • Page 6(2) Detail of cable K95 Interface cable of βiSVSP and power failure backup module SVSP JX6 JX1A (9) *CRDY (9) (12) 0V (10) Connector Example (HONDA) Connector Example (HONDA) Connector PCR-E20FA Connector PCR-E20FA Hausing PCR-V20LA Hausing PCR-V20LA Cable specification: 0.09mm2 twisted pair sealed