04 03.05.13
TSUGESHITA
CORRESPONDENCE TO CALENDAR
03 03.05.13
TSUGESHITA
ADD MIN.OFFTIME, PMC PRAMETER
06 04.09.08
TOKITO
ADD. FOR ALM.4073
05 03.12.24
SUZUKI
ADD.APPLIED SOFTWARE AND EDIT.
EDIT. DATE DESIG. DESCRIPTION APPRO.
FANUC LTD 005/10
TITLE
A-81053E-053
SHEET
AUTOMATIC AGING FUNCTION
DRAW. No.
6. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
15008 EGE
EGE This bit sets “enable” and “disable” of Automatic Aging function
1: enable
0: disable
15320 Power command for power calibration( This is enable at EGE=1)
Power command to get power calibration efficiency
When automatic aging function is effective, power calibration efficiency is calculated
after aging.
Unit : W
Setting range : 0 - 7000
Standard setting : 1000: C1000-E
1500 : C1500B
2000 : C2000B,C2000C,C2000-E
3000 : C3000C,C3000D
4000 : C4000A,C4000-E,C6000A
6000 : C6000B
15321 Pulse frequency command for power calibration(This is enable at EGE=1)
Pulse frequency command to get power calibration efficiency
Unit : W
Setting range : 5 - 2000
Standard setting : 100
15322 Pulse duty command for power calibration(This is enable at EGE=1)
Pulse duty command to get power calibration efficiency
Unit : %
Setting range : 0 - 100
Standard setting : 100
(Add Model on 03rd Ed)